Products List

LASER WAVELENGTH METERS

821 Series Laser Wavelength Meters (pulsed and CW lasers)

Model 821B-VIS
(wavelength accuracy: ¡¾ 0.02 cm-1, wavelength range: 350 –1100 nm, open aperture input)
Model 821B-NIR
(wavelength accuracy: ¡¾ 0.02 cm-1, wavelength range: 630 –1700 nm, open aperture input)
LC-8-VIS
(Fiber-optic input coupler, wavelength range: 400 –1100 nm)
LC-8-NIR
(Fiber-optic input coupler, wavelength range: 630 –1700 nm)
LC-8-UV
(Fiber-optic input coupler, wavelength range: 370 –1100 nm)

621 Series Laser Wavelength Meters (CW lasers)

Model 621A-VIS
(wavelength accuracy: ¡¾ 0.2 ppm, wavelength range: 350 –1100 nm, fiber-optic input)
Model 621A-NIR
(wavelength accuracy: ¡¾ 0.2 ppm, wavelength range: 500 –1700 nm, fiber-optic input)
Model 621A-IR
(wavelength accuracy: ¡¾ 0.2 ppm, wavelength range: 1.0 –5.0 m, open aperture input)
Model 621B-VIS
(wavelength accuracy: ¡¾ 1.0 ppm, wavelength range: 350 –1100 nm, fiber-optic input)
Model 621B-NIR
(wavelength accuracy: ¡¾ 1.0 ppm, wavelength range: 500 –1700 nm, fiber-optic input)
Model 621B-IR
(wavelength accuracy: ¡¾ 1.0 ppm, wavelength range: 1.0 –5.0 m, open aperture input)
Model 621B-MIR
(wavelength accuracy: ¡¾ 1.0 ppm, wavelength range: 4.0 –11.0 m, open aperture input)

521 Series Laser Wavelength Meters (CW lasers)

Model 521-VIS
(wavelength accuracy: ¡¾ 10 ppm, wavelength range: 350 –1100 nm, fiber-optic input)
Model 521-NIR
(wavelength accuracy: ¡¾ 10 ppm, wavelength range: 500 –1700 nm, fiber-optic input)

721 Series Laser Spectrum Analyzers

Model 721A-VIS
(wavelength accuracy: ¡¾ 0.2 ppm, wavelength range: 350 –1100 nm, fiber-optic input)
Model 721A-NIR
(wavelength accuracy: ¡¾ 0.2 ppm, wavelength range: 500 –1680 nm, fiber-optic input)
Model 721A-IR
(wavelength accuracy: ¡¾ 0.2 ppm, wavelength range: 1.3 –5.0 m, open aperture input)
Model 721B-VIS
(wavelength accuracy: ¡¾ 0.75 ppm, wavelength range: 350 –1100 nm, fiber-optic input)
Model 721B-NIR
(wavelength accuracy: ¡¾ 0.75 ppm, wavelength range: 500 –1680 nm, fiber-optic input)
Model 721B-IR
(wavelength accuracy: ¡¾ 0.75 ppm, wavelength range: 1.3 –5.0 m, open aperture input)
Model 721B-MIR
(wavelength accuracy: ¡¾ 1.0 ppm, wavelength range: 4.0 –11.0 m, open aperture input)

DWDM OPTICAL WAVELENGTH METERS

228 Series Optical Wavelength Meters (CW single-wavelength)
Model 228A
(wavelength accuracy: ¡¾ 0.2 ppm, wavelength range: 1250 –1650 nm, fiber-optic input)
Model 228B
(wavelength accuracy: ¡¾ 0.75 ppm, wavelength range: 1250 –1650 nm, fiber-optic input)

FABRY-PEROT INTERFEROMETER MIRRORS/ACCESSORIES

FP Series Fabry-Perot Interferometer Mirrors

FP-50M-VIS
(mirror diameter: 50.8 mm, center wavelength: 450 –1200 nm, coating bandwidth: 100 nm)
FP-50M-NIR
(mirror diameter: 50.8 mm, center wavelength: 1200 –1900 nm, coating bandwidth: 150 nm)
FP-50M-IR
(mirror diameter: 50.8 mm, center wavelength: 1.9 –3.5 m, coating bandwidth: 300 nm)
FP-50M-FIR
(mirror diameter: 50.8 mm, center wavelength: 3.5 –12.0 m, coating bandwidth: 500 nm)

FP Series Fabry-Perot Interferometer Mirror Holders

FP-50H
(Invar mirror holders for 50.8 mm diameter mirror set)

OPTICAL COMPONENTS
LC Series Fiber-Optic Laser Couplers

LC-1-VIS
(Input coupler, wavelength range: 400 –1100 nm)
LC-1-NIR
(Input coupler, wavelength range: 500 –1700 nm)
LC-1-UV
(Input coupler, wavelength range: 350 –1100 nm)
LC-2-VIS
(Output coupler, wavelength range: 400 –1100 nm)
LC-2-NIR
(Output coupler, wavelength range: 500 –1700 nm)
LC-2-UV
(Output coupler, wavelength range: 3