¢º Spectrophotometer Calibration Filters

  For verification of T scales of visible absorption spectrometers

  For verification of R scales of visible absorption spectrometers

  Set contains 3 glass filters

  Mounted filters with black anodized holder

 

 

Inquiry

 
Spectrophotometric Standards
NIST-Traceable Calibration Filters
AC-930 and AC-1930

 



These Spectrophotometric glass standards are intended for use as secondary standards for the verification of the transmittance and absorbance scales of visible absorption spectrometers.
 
Each set contains 3 glass filters for the verification of transmittance and 1 clear holder for use as a balancing filter. The transmission value of each filter is certified by measuring it on a spectrophotometer that has been calibrated with standards that are directly traceable to the NIST.
 
Each filter is mounted in a black anodized aluminum holder, which is compatable with the 1cm cuvette holder, that is supplied with most spectrophotometers. Individual filters are suppled with removeable shutters to protect the filter glass from damage.
 
Every filter set is shipped with a Certificate of Calibration stating the transmission value of each filter at five different wavelengths (440nm, 465nm, 546.1nm, 590nm & 635nm). The transmission accuracy of each filter is certified to be within ¡¾1%.
 
All filter sets are shipped in black anodized metal cannisters which provides maximum protection during shipment and non-use.
AC-930
The AC-930 filter set consists of three individual absorption glass filters mounted in a metal holder, and one blank holder which can be used as a balancing filter. All filters are made of uncoated Schott NG-4 and NG-5 Filter Glass and are polished over the central 5mm X 20mm filter area to a TWF of one wave or better at 633nm and parallelism of 1 arc minute or better. The nominal transmittance values of these filters are 10%, 20%, 30% and are sufficient to accurately verify absorption spectrophotometers, with maximum spectral bandwidths from 2.2nm to 6.5nm, for the five wavelengths at which the transmittance values are certified.. Each filter is certified for transmittance at five wavelengths: 440.0nm. 465.0nm, 546.1nm, 590.0nm, and 635.0nm.

AC-1930
The AC-1930 filter set consists of three individual absorption glass filters mounted in a metal holder, and one blank holder which can be used as a balancing filter. All filters are made of uncoated Schott NG-4 and NG-5 Filter Glass and are polished over the central 5mm X 20mm filter area to a TWF of one wave or better at 633nm and parallelism of 1 arc minute or better. The nominal transmittance values of these filters are 1%, 3%, 50%, and are sufficient to accurately verify absorption spectrophotometers, with maximum spectral bandwidths from 2.2nm to 6.5nm, for the five wavelengths at which the transmittance values are certified. Each filter is certified for transmittance at five wavelengths: 440.0nm. 465.0nm, 546.1nm, 590.0nm, and 635.0nm.

RECALIBRATION

The certification for each filter set is valid for a period of 2 years from the date of certification. The filters sets should be returned to Andover Corporation for cleaning and recalibration upon expiration of the certification period. Andover will supply a new Certificate of Calibration certifying the Transmittance Value and Transmittance Density of each filter at the original five wavelengths.

Contact the Quality Control Department of Andover Corporation at (888) 893-9992 (Toll Free) for a Recalibration Return Number.

Please use the original Andover shipping container when returning these filters for recertification.

 